String Sizing Tool

Work out how many panels can safely go in each string for your climate, and check the currents on each MPPT. Compare two panels side by side. Companion tool to Chapter 4 of Practical Guide to Solar Panel Installation: Sizing Your Strings.

Results

Site conditions

The coldest early morning your site sees.
Panels run 25–35 °C above air temperature in full sun.
1.25 is the usual allowance.

Inverter from the datasheet

Panels and your design STC values from the datasheets

How it works

Voc,cold = Voc × [1 + β/100 × (Tmin − 25)] → Nmax = Max DC input voltage ÷ Voc,cold (round down)
Vmp,hot = Vmp × [1 + γ/100 × (Thot − 25)] → Nmin = MPPT minimum ÷ Vmp,hot (round up)

β is the Voc temperature coefficient and γ the Pmax coefficient, used for Vmp because datasheets rarely give one; it errs on the safe side. Operating current = strings × Imp, checked against the MPPT's max operating current. Short-circuit current = strings × Isc × safety margin, checked against the MPPT's max short-circuit current. The most panels on the inverter is the smaller of (MPPTs × strings per MPPT × max string length) and (max PV access power ÷ panel power).

Example values: Sunsynk SYNK-16K-SG01LP1PLUS datasheet v.2; Canadian Solar CS6W-TB-AG v2.0C2 and CS7N-TB-AG v1.91 datasheets.