Inverter Sizing Calculator

Check your string design against the inverter's limits, make sure it copes with your loads and start-up surges, and spot missing features before you buy. Companion tool to Chapter 4 of The Practical Solar Guide: Choosing an Inverter.

All checks

Solar panel

Copy these from your panel datasheet (the STC column).

Inverter

Surge is often given as "2× rated for 10 s": enter it in kW (e.g. 2 × 12 = 24).
"2+2+2" means 3 MPPTs × 2 strings.

Weather allowances (rules of thumb)

Allow ~10% (0.1) above Voc for cold mornings. Use more in very cold climates.
Working voltage falls ~12% (0.12) on a hot afternoon. Use more in very hot climates.

Allowed string length for this panel and inverter

String check

One row per MPPT on your inverter (set by "Number of MPPTs" above). Leave unused MPPTs blank. Each MPPT should carry identical strings on one roof face (Chapter 4, section 4.5).

What might run at the same time during an outage

Motors and compressors (fridges, pumps, aircons) draw several times their running power for a moment when they start. A blank multiplier on a motor load uses 3.

Will the inverter cope?

The suggested size adds 25% headroom and never goes below 8 kVA, the sensible minimum for most homes today (Chapter 4, section 4.4). When the grid is on, a hybrid inverter can often pass grid power through for bigger peaks. These checks are for outages, when the inverter is on its own.

Features checklist

Tick what you need, then what the inverter you're quoted actually offers.