RX-Timber Eurocode Suite A software package for the calculation and structural analysis of timber members

The exchange rate used to calculate the indicative Rand price is
The total once off price of the RX-Timber Eurocode Suite is and excludes the price of add-on modules. A service contract is optional, and will ensure free updates for each year that the service contract is renewed. Product upgrades are not covered by the service contract - only product versions less than 2 years old are supported.
Price is based on the current Rand/Euro exchange rate

The modules within the RX-Timber Eurocode Suite

Design of Glued-Laminated Beams

The stand-alone module RX-TIMBER Glued-Laminated Beam designs glued-laminated beams for the ultimate and the serviceability limit state according to EN 1995-1-1:2004-11 (EC5) or DIN 1052:2008-12. In addition, the fire protection design according to EN 1995-1-2 or DIN 4102, part 22, is available.

Learn More

Calculation of Coupled Purlins and Continuous Beams

The stand-alone module RX-TIMBER Purlin designs beams for the ultimate and the serviceability limit states as well as for fire protection according to EN 1995-1-1:2009 (EC5) and DIN 1052:2008-12. In addition to the accurate and automatically performed generation of loads including corresponding combinations of relevant load cases, RX-TIMBER Purlin determines the coupling elements required in the coupling zone.

Learn More

Calculation of Three-Hinged Frames with Finger Joint Connections

The stand-alone module RX-TIMBER Frame designs beams for the ultimate and the serviceability limit states according to EN 1995-1-1:2004-11 (EC5) or DIN 1052:2008-12. In addition, the fire protection design according to EN 1995-1-2 or DIN 4102, part 22, is available.

Learn More

Calculation of Truss Bracings for Stiffening

The stand-alone program RX-TIMBER Brace performs the ultimate and the serviceability limit state design as well as the fire protection design for stiffening bracings in accordance with the European standard EN 1995-1-1:2004-11 (EC 5). Optionally, it is possible to perform the designs according to the German standard DIN 1052:2008-12.

Learn More

Calculation and Design of Continuous Beams According to EN 1995-1-1:2004-11 (EC5) or DIN 1052:2008-12

The stand-alone module RX-TIMBER Continuous Beam designs girders according to DIN 1052:2008 and EN 1995-1-1:2004 (EC5). At this, the ultimate and serviceability limit state design is carried out as well as the fire protection design.

Learn More

Design of Timber Columns According to EN 1995-1-1:2004-11 (EC5) or DIN 1052:2008-12

The stand-alone module RX-TIMBER Column designs rectangular and round timber columns according to EN 1995-1-1:2004 (EC5) and DIN 1052:2008. At this, the ultimate and serviceability limit state design is carried out as well as the fire protection design.

Learn More


Stay connected with us >>